SIEMENS Energy & Automation
10-63
SIMOREG DC Master Base Drive Panel Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
P615
*
(G165)
Source for EMF controller setpoint
Selection of connectors to be injected as the
EMF controller setpoint
. The
connectors selected in the four indices are added.
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=
i001: 289
i002: 0
i003: 0
i004: 0
Type: L2
P052 = 3
P051 = 40
Offline
P616
*
(G165)
Source for actual EMF controller value
Selection of connector to be injected as the
actual EMF controller value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=286
Type: L2
P052 = 3
P051 = 40
Offline
Configuring of injection of acceleration value
P619
*
(G153)
Source for acceleration injection value
Selection of connector to be applied as the
acceleration injection value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=191
Type: L2
P052 = 3
P051 = 40
Offline
Speed controller
Speed controller, setpoint/actual value deviation
Function:
The connectors selected in parameters P621 and P622 are added and those selected in P623 and 624 subtracted
P620
*
(G152)
Source for speed controller setpoint/actual value deviation
Selection of connector to be injected as the control deviation
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=165
Type: L2
P052 = 3
P051 = 40
Offline
P621
*
(G152)
Source for speed controller setpoint
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=176
Type: L2
P052 = 3
P051 = 40
Offline
P622
*
(G152)
Source for speed controller setpoint
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=174
Type: L2
P052 = 3
P051 = 40
Offline
P623
*
(G152)
Source for actual speed controller value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=179
Type: L2
P052 = 3
P051 = 40
Offline
P624
*
(G152)
Source for actual speed controller value
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Speed controller: Filtering of setpoint and actual value, band-stop filters
P625
*
FDS
(G152)
Source for speed controller setpoint
Selection of connector to be injected as the input signal for speed setpoint
filtering
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=170
Type: L2
P052 = 3
P051 = 40
Offline
P626
*
FDS
(G152)
Source for actual speed controller value
Selection of connector to be injected as the input signal for actual speed
value filtering
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=167
Type: L2
P052 = 3
P051 = 40
Offline