Parameter settings
5.2 Configuration via STEP 7 (Basic/Professional)
SIMATIC RF170C
Operating Instructions, 02/2022, J31069-D0176-U001-A6-7618
33
Table 5- 2
Parameters in the "Frame" parameter group
Parameter
Parameter value
Default value
Description
Data bits
7
8
8
Selection of the number of bits on which a
character is represented.
Parity
None
Odd
Even
Fixed value 1
Fixed value 0
None
Parity selection
A sequence of data bits can be expanded by a
parity bit. With its value "0" or "1", the parity bit
is added to the sum of all bits (data bits and
parity bits) to form a defined status. This
increases data reliability.
•
None:
Data is sent without a parity bit.
•
Odd:
The parity bit is set so that the sum of the
data bits (including the parity bit) is odd
when the signal state is "1".
•
Even:
The parity bit is set so that the sum of the
data bits (including the parity bit) is even
when the signal state is "1".
•
Fixed value 1:
The parity bit is set permanently to the value
"1".
•
Fixed value 0:
The parity bit is set permanently to the value
"0".
Stop bits
1
2
1
Selection of the number of stop bits that
indicate the end of a character.
The stop bits are appended to every transferred
character during transmission.