Scenario C:
1. Parameterization:
1.1 Monitored motion:
Rotational
1.2 Encoder type:
Rot. encoder
1.3 Encoder selection:
E2
1.5 Encoder resolution:
512 pulses/rev.
1.6 Initiator settings:
Resolution E2
4 pulses/rev.
1.4 Lead//transmission:
Transmission:
50:1
The speed limits (rpm) to be set refer to the speed at the encoder.
Scenario D:
1. Parameterization:
1.1 Monitored motion:
Rotational
1.2 Encoder type:
Rot. encoder
1.3 Encoder selection:
Encoder
1.5 Encoder resolution:
512 pulses/rev.
1.4 Lead//transmission:
Transmission:
not relevant since only one encoder has been
selected.
The speed limits (rpm) to be set refer to the speed at the encoder.
Scenario E: Monitoring the slide to, e.g. 3 m/min.
1. Parameterization:
1.1 Monitored motion:
Rotational
1.2 Encoder type:
Rot. encoder
1.3 Encoder selection:
E2
1.5 Encoder resolution:
512 pulses/rev.
1.6 Initiator settings:
Resolution E2
4 pulses/rev.
1.4 Lead//transmission:
Transmission:
50:1
5RWDWLRQDO
PRQLWRULQJWKUHVKROG
7UDQVODWLRQDOPRQLWRULQJWKUHVKROG[WUDQVPLVVLRQUDWLR
/HDG
USP
PPLQ[
PPUHY
Operation
7.3 Configuring
3TK2810-1 safety-related speed monitor
Equipment Manual, 05/2020, NEB926246402000/RS-AE/007