B
B.1
Tightening torques for screw and bolt connections
Bolt locking devices
● Refit nuts or bolts that are mounted together with locking, resilient, and/or force-distributing
elements with identical, fully-functional elements when re-assembling. Always renew keyed
elements.
● When screwing together threads secured with a liquid adhesive, use a suitable medium
such as Loctite 243.
● Always use suitable securing devices or removable adhesives (e.g., Loctite 243) when
installing fixing bolts with a clamping length of less than 25 mm. The clamping length is
taken as the distance between the head of the bolt and the point at which the bolt is screwed
in.
Tightening torques
The bolted connections with metal contact surfaces, such as end shields, bearing cartridge
parts, terminal box parts bolted onto the stator frame, should be tightened to the following
torques, depending on the thread size:
Table B-1
Tightening torques for bolted connections with a tolerance of ±10%.
Case
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
M36
M42
M48
M56
A
1.2
2.5
4
8
13
20
40
52
80
150
-
-
-
-
Nm
B
1.3
2.6
4.5
11
22
38
92
180
310
620
1080 1700 2600 4200 Nm
C
3
5
8
20
40
70
170
340
600
1200 2000 3100 4700 7500 Nm
SIMOTICS TN Series N-compact 1LH8
Operating Instructions 06/2017
131
Summary of Contents for 1PQ8
Page 2: ...06 06 2017 10 16 V15 00 ...
Page 92: ...Operation 8 10 faults SIMOTICS TN Series N compact 1LH8 92 Operating Instructions 06 2017 ...
Page 130: ...Service and Support SIMOTICS TN Series N compact 1LH8 130 Operating Instructions 06 2017 ...
Page 134: ...Quality documents SIMOTICS TN Series N compact 1LH8 134 Operating Instructions 06 2017 ...
Page 139: ......