9.4.9
Reassembly: Miscellaneous information
• Position all rating and supplementary plates as in the original state.
• Where relevant, fix electric cables.
• Check the tightening torques of all screws, as well as those of screws that have not been
released.
9.4.10
Optional add-on units
Note
Further documents
Observe all of the other documents provided with this machine.
You can find additional operating instructions here: Siemens Industry Online Support on the
Web (Page 12)
9.4.10.1
Mounting a brake (optional)
Table 9-5
Assigning standard brakes for 1LE5 machines
Shaft height
Brake type
Size assignment of the
brakes
280
KFB100
100
280
FDX40
40
315
SFB 250-SH
250
355
SFB 400-SH
400
9.4.11
O-ring seal
If O-ring seals are present, you should check that they are in perfect condition and that the O-ring
seals are properly seated in the grooves between the components. Replace damaged O-ring
seals.
O-ring seals can be present on the following components, for instance:
• Adapters, tapers
• Entries, glands
• Bearing seals
• End shield seals
Maintenance
9.4 Corrective maintenance
1LE5, 1PC4 shaft heights 280 ... 355
112