EXC-GT – FM super-compact transmitter series
User’s manual – Page 43 of 98
In the above example, if the synthesizer is unlocked for a
Delay
of 31 seconds, an alarm will be issued.
To set the synthesizer unlock alarm:
1)
Ensure that the
EDIT
option is selected; otherwise, turn the knob to select it, then press to confirm. A value will be indicated
after
Delay
.
2)
Turn the knob to change the time according to your requirements, then press to confirm.
3)
Using the knob, select
OK
to save the settings,
EDIT
to make further changes, or
ABORT
to exit without saving the new
settings, then press to confirm (for further details regarding these commands, see
2
9.4.a).
MPX
From this screen, you can personalize the insufficient modulation alarm. Two parameters can be set:
Mpx Alarm
– the threshold below which modulation, expressed in dB in reference to a deviation of 75 KHz (0dB = 75 KHz), is considered
insufficient.
Delay
– the time in seconds after which, if modulation remains insufficient, an alarm is issued.
In the above example, the alarm is issued only when modulation constantly remains at least 16 dB below 75 KHz for 60 seconds.
To set the insufficient modulation pre-alarm and alarm:
1)
Ensure that the
EDIT
option is selected; otherwise, turn the knob to select it, then press to confirm. A value will be indicated
after
Mpx Alarm
.
2)
Turn the knob to change the modulation to a level that is considered insufficient for your requirements, then press to confirm.
A value will be indicated after
Delay
.
3)
Turn the knob to change the time interval according to your requirements, then press to confirm.
4)
Using the knob, select
OK
to save the settings,
EDIT
to make further changes, or
ABORT
to exit without saving the new
settings, then press to confirm (for further details regarding these commands, see
2
9.4.a).
RESET LOG
As previously mentioned, this menu does not allow you to configure alarms, but rather to delete the alarm history.
When you access this menu, two simple commands are available by turning the knob:
YES
– the alarm history will be deleted. The message
waiting…
will appear while the history is being deleted.
NO
– the alarm history will not be deleted (in cases of accidental access to the sub-menu, where there is no actual need to delete the history).
After either command is selected, the display will return to the
SET ALARM
sub-menu.
,
The alarm/event history delete function does not request confirmation; as such, be careful not to accidentally delete
the history.
10.3.m ETHERNET
(LAN)
setting
Used to set parameters related to the Ethernet LAN interface.