16
MSA400
Original operating instructions
03.2015
Cleaning and maintenance
Important:
Water must not enter the MSA400 system during cleaning!
Only clean the external housing components of the system with a lightly damp, soft, lint-free cloth. Do not use any corrosive
chemicals, aggressive cleaning agents or substances containing solvents, as this could damage the surface of the housing.
Malfunctions
In case of a malfunction, do not open the device or try to repair it under any circumstances.
If the problem is not listed in the table below, please contact your window specialist or SIEGENIA directly: Tel. +49 271
3931-0
Malfunction
LED indicator
Possible cause
Solution
MSA400 not functioning
Off
No power supply
Check power supply
Off
Infrared remote control not
taught in
Teach in infrared remote control
(see page 13)
Flashes red
MSA400 not initialised
Perform reference run
(see page 15)
Flashes 2x green/3x
red
MSA400 overheated
Let MSA400 cool down
Flashes red/green
MSA400 not initialised
Interrupt power supply for at
least 10seconds, then perform a
reference run as well as a
calibration/teach-in run
MSA400 aborts closing/
opening and moves in opposite
direction for 4 seconds
Off
Obstacle is blocking the
sash’s traverse path
Remove obstacle and operate
MSA400 system again
Technical data
Specification for a MSA400
Supply voltage
120 - 240 V AC, 22 W
Operating voltage
24 V DC
Max. displacement force
Approx. 50 N (depending on sash weight and friction)
Traverse speed
Approx. 150 mm/s
Temperature range
-5 °C to +50 °C
Jam protection
electronic overload cut-off device
(current limiter in accordance with standard)
Protection category
IP 20
Connection to AC mains power supply (at factory)
Euro plug, 5 m cable length