background image

Original operating instructions 

MSA400

03.2015

3

Contents

Correct use ...................................................................................................................................................................................... 4
Safety notices .................................................................................................................................................................................. 5
Description of device and functions ............................................................................................................................................... 6
Operating and display elements .................................................................................................................................................... 7
First operation .................................................................................................................................................................................. 8
Operation using operating push button .......................................................................................................................................10
Programming .................................................................................................................................................................................13
Reset the sash position ..................................................................................................................................................................15
Cleaning and maintenance ..........................................................................................................................................................16
Malfunctions ..................................................................................................................................................................................16
Technical data ...............................................................................................................................................................................16
Information concerning product liability ......................................................................................................................................17

Summary of Contents for MSA400 smart

Page 1: ...Window hardware Door hardware Sliding door hardware Ventil ation technology Building technology Building technology Original operating instructions MSA400 Motorised Sliding System...

Page 2: ......

Page 3: ...ces 5 Description of device and functions 6 Operating and display elements 7 First operation 8 Operation using operating push button 10 Programming 13 Reset the sash position 15 Cleaning and maintenan...

Page 4: ...MSA400 checked and repaired by qualified specialists only When you operate the unit for the first time you must carry out a reference run as well as a calibration teach in run in order to determine t...

Page 5: ...an may perform any work on the 230 V AC mains power supply Current local regulations such as VDE 0100 of the VDE in Germany must be observed Relevant country specific regulations must be strictly foll...

Page 6: ...position Opens the sliding sash to an intermediate position which can be program med to any position Closing the sliding sash without locking Closes the sliding sash without locking it This function...

Page 7: ...e g after a power failure Operating push button The operating push button is used to trigger functions open close etc and is also used during programming Infrared remote control optional The supplied...

Page 8: ...gin the reference run If necessary slide the sash to this position manually 2 Supply power to the MSA400 system 3 Press the operating push button The reference run starts During the reference run the...

Page 9: ...e sash to this position manually 3 Press the Prog button the LED flashes green 4 Press and hold the operating push button for approx 11 seconds until a short acoustic signal sounds 4 times in successi...

Page 10: ...le the sliding sash is opening press the operating push button once The sliding sash stops 1 x Opening sliding sash to intermediate position Note The desired intermediate position must be programmed o...

Page 11: ...see Teach in close function without locking on 15 With sliding sash open press the operating push button once The sliding sash closes the LED lights up red 1 x Closing and locking the sliding sash op...

Page 12: ...ored until a different group is selected Button Function Control all groups Control group 1 Control group 2 Control group 3 Control group 4 Control group 5 Button Function Intermediate position OPEN C...

Page 13: ...n succession 3 Release the operating push button the LED flashes red 4 Within 10 seconds press the button button 1 5 for the group to be deleted on the infrared remote control 5 A long acoustic tone s...

Page 14: ...the operating push button for approx 8 seconds until a short acoustic signal sounds 3 times in succession 4 Release operating push button the sliding sash opens 5 At the desired intermediate position...

Page 15: ...on the LED flashes green 3 Press and hold the operating push button for approx 5 seconds until a short acoustic signal sounds 2 times in succession 4 Release the operating push button 5 Press and hold...

Page 16: ...l not taught in Teach in infrared remote control see page 13 Flashes red MSA400 not initialised Perform reference run see page 15 Flashes 2x green 3x red MSA400 overheated Let MSA400 cool down Flashes...

Page 17: ...tled or partly dismantled and the defect is due to the changes made Disclaimer of liability The system and its components are subject to stringent quality controls As a result they function reliably a...

Page 18: ......

Page 19: ......

Page 20: ...9 2811312 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 44...

Reviews: