02.2019
6/64
H39.MFVRS004EN-00
Multi-point locks, key operated
Assembly instructions
BS 230X, BS 250X, BS 260X
1.11
Applicable documents
For the installation of the multi-point lock, it is essential
to observe all assembly and operating instructions that
are enclosed with other (optional) components. The
instructions of the door manufacturer and for other ac-
cessories from other manufacturers are also applicable.
1.12
Appropriate disposal
•
The multi-point lock and the optional accessories
should not be disposed of with household waste.
Comply with the current local and national regula-
tions.
•
The packaging consists of raw materials that can be
recycled and can be taken to the local waste paper
disposal site.
1.13
Causes of damage
Do not drill through the door leaf in the area of the gear box when the lock
or the multi-point lock is installed.
The spindle must not be hit through the lock nut with force.
The door leaf must not be carried using the lever handle as a grip.
1.9
Other types of indicators
Below is a list of symbols used in these instructions and
their meanings:
•
Items of text following this marker are found in lists.
–
Items of text following this marker are found in
subordinate lists.
f
Items of text with this marking in front of them are
instructions that must be followed in the specified
order.
Cross reference
„“ A separate cross reference is enclosed by quotati-
on marks.
() A cross reference in the flow text is enclosed by
brackets.
1.10
Screw recommendations
Aluminium:
SKG** Ø ≥ 4.8 mm
Aluminium profile min. 2 mm wall thickness
Timber:
SKG** Ø 4.0 mm x 40 mm
SKG*** Ø 4.5 mm x 45 mm
SKH certified
PVC:
SKG** Ø ≥ 4.2 mm
Steel reinforcement min. 1.5 mm wall thickness