The deadbolt does not grip properly into the opening of the safety catch
f
Check the airgap for adherence to dimensions (see chapter 4.13 „Adjustment of airgap“ from page 50).
•
If the airgap is not compliant with the specified dimensions, it must be adjusted.
f
Repeat the test step with the airgap correctly adjusted.
•
If the deadbolt continues to fail to grip into the opening of the safety catch, the additional deadbolt lock TR
must be checked by KFV.
6.5
Functional disorder of the additional deadbolt lock TR
Sluggishness during locking and release
f
Dismount the multi-point lock and lock and release the T2 safety lock in the dismounted condition.
•
If this sluggishness persists, the additional deadbolt lock must be checked by KFV.
•
If the sluggishness does not persist when the lock is dismounted, the additional deadbolt lock TR is technically
OK.
f
Check the routed pocket of the additional deadbolt lock TR for adherence to dimensions.
•
If the routed pocket does not comply with the specified dimensions, it must be reworked.
f
Repeat the test step with the reworked routed pocket.