630F & 634F Exit Device Trim
Installation Instructions
1.
Check box for components.
2.
After marking door inside face for device location (Device Instructions),
carry “ Vertical Reference Centerline” from inside door face. Follow
steps 2a. and 2b., shown below.
3.
Transfer Horizontal Reference Centerline from inside to outside door face.
4.
Align trim template and tape to outside door face.
5.
Spot holes and prepare door for trim
6.
Mount trim to door thru holes “A” with (2) mounting screws as shown in
Fig. 2. Use the remaining (3) oval headed screws and finish washers to
secure the trim to the door surface thru location “B” as shown in Fig. 2,
the third screw and washer attaches to the hole located at the bottom
of the trim.
7.
Continue as shown in device instructions.
Installation Instructions
Figure 2
2
2
2-3/4
(70)
630F Trim
2-3/4
(70)
634F Trim
(Push-Pull Door
when dogged)
630F Trim
634F Trim
Escutcheon
Assembly
(2) 1/4-20 Pan Head
Machine Screws
Packed with device.
2 STUDS TOWARDS
LOCK EDGE
(3) 1/4-20 Oval Head
2 STUDS AWAY
FROM LOCK EDGE
(2) #14 Finishing
Washers
Escutcheon
Assembly
(2) 1/4-20 Pan Head
Machine Screws
Packed with device.
2 STUDS TOWARDS
LOCK EDGE
(2) 1/4-20 Oval Head
2 STUDS AWAY
FROM LOCK EDGE
Attention Installer
Any retrofit or other field modification to a fire
rated opening can potentially impact the fire
rating of the opening, and Yale Locks &
Hardware makes no representations or
warranties concerning what such impact may be
in any specific situation. When retrofitting any
portion of an existing fire rated opening, or
specifying and installing a new fire-rated
opening, please consult with a code specialist or
local code official (Authority Having Jurisdiction)
to ensure compliance with all applicable codes
and ratings.
80-8470-0634-000 (11-18)