background image

11

AEROPAC 60

AEROPAC 90, AEROPAC 60A

 

or

 

AEROPAC 90A

The following form part of the Product Pack Contents:

– Mounting jig with installation instructions

– Mounting kit, consisting of two dowels and screws 

– Euro small device supply line, 1500 mm length

– Hexagon socket screw key, 3 mm

– Weather grill 80*

– Ventilating tube (PVCu-tube) Ø 80 mm*

* If you have purchased AEROPAC in single units, you may order these accessories from 

SIEGENIA-AUBI (see page 14)

The AEROPAC

 

is a top-class ventilation product.

The AEROPAC is a ventilation device with a radial fan. The device will have the 
following characteristics, depending on the type of model:

AEROPAC 60

approx. 30 - 60 m

3

/h air volume

AEROPAC 90

approx. 30 - 135 m

3

/h air volume 

both with foam material filter

AEROPAC 60A approx. 20 - 50 m

3

/h air volume

AEROPAC 90A approx. 20 - 110 m

3

/h air volume 

both with activated carbon filter

The equipment has the following features:

– Sound absorption

– Filtration of dust and waste gas odours 

– Low sound during operation 

– Easily adjustable

Scope of delivery

Properties

Tec

hn

ic

a

l s

p

ec

ification

s an

d co

lo

urs

 are

 s

ub

je

ct to c

han

ge

GB

Summary of Contents for AEROPAC 60

Page 1: ...AEROPAC Bedienungsanleitung Operating Instructions Gebruiksaanwijzing DE GB NL H4035 0010de_gb_nl 5...

Page 2: ...nleitung sind zu beachten Gebrauchen Sie das Ger t nur in technisch einwandfreiem Zustand Nehmen Sie keine Ver nderungen an den Ger tekomponenten vor Achten Sie darauf dass die Luft ffnungen frei blei...

Page 3: ...sel stromnetzes Ersetzen Sie das Netzkabel umgehend falls es Knickstellen aufweist oder die Ummantelung besch digt ist Gelangt ein fester Gegenstand oder Fl ssigkeit in das Ger te innere brechen Sie d...

Page 4: ...m AEROPAC erzeugen Sie ein angenehmes Raumklima Bei geschlossenem Fens ter l ften Sie zugfrei sicher energiesparend und ohne L rm von drau en Der AEROPAC ist ein Bel ftungsger t mit einem Radialgebl s...

Page 5: ...ach Wetterlage erh ht Winddruck die Luftstr mung in den Raum Ver ndern Sie die Schieberpositionen um die ge w nschte Luftmengeeinzustellen Gebl sebetrieb ffnen Sie zumindest eine der beiden seitlichen...

Page 6: ...t ziehen Sie einfach an der unteren Kante der Haube und klappen Sie sie nach vorne hoch Abb 1 B ziehen Sie die Haube in dieser Lage vom Ger t ab Abb 2 Der Filter ist lose um den Ventilatork fig gelegt...

Page 7: ...x T 405 x 250 x 115 mm Elektrischer Anschluss AC 230 V 50 Hz 0 05 Ampere Schutzklasse 2 AC 230 V 50 Hz 0 11 Ampere Schutzklasse 2 Leistungsaufnahme ca 9 Watt max 25 Watt Ger tebuchse an der Unterseite...

Page 8: ...n daher bei regelgerechter Anwendung zuverl ssig und sicher Unsere Haftung f r Mangelfolgesch den und oder Schadensersatzanspr che schlie en wir aus es sei denn wir h tten vors tzlich oder grob fahrl...

Page 9: ...documentation from SIEGENIA AUBI Use the unit only in the technically perfect state Do not make any changes on the components of the unit Ensure that the air openings remain clear and are not blocked...

Page 10: ...mains socket Immediately replace the power supply cable if it is kinked or if the jacketing is damaged If a solid object or liquid gets into the inside of the unit switch off and disconnect the unit...

Page 11: ...OPAC is a top class ventilation product The AEROPAC is a ventilation device with a radial fan The device will have the following characteristics depending on the type of model AEROPAC 60 approx 30 60...

Page 12: ...outside flows into the room The wind pressure of the airflow into the room changes according to the weather conditions Change the slider positions to set the desired air quantity Fan operation Open a...

Page 13: ...ring actuated lock so that the appliance can be opened easiliy for a filter change Simply pull on the lower edge of the hood and fold it up to the front Fig 2 The filter sits loosely on the ventilator...

Page 14: ...x T 405 x 250 x 115 mm Power supply AC 230 V 50 Hz 0 05 Ampere Protection class 2 AC 230 V 50 Hz 0 11 Ampere Protection class 2 Power consumption approx 9 Watt max 25 Watt Cable entry at the bottom o...

Page 15: ...We rule out our liability for consequential harm caused by a defect and or for claims for damages unless we have acted wilfully or with gross negligence or respectively are responsible for injury to...

Page 16: ...lleen met de oorspronkelijke accessoires van SIEGENIA AUBI Gebruik de AEROPAC alleen als deze technisch foutloos is Breng geen veranderingen aan onderdelen van het apparaat aan Let erop dat minstens n...

Page 17: ...deze knikpunten vertoont of het omhulsel beschadigd is Als er een vast voorwerp of vloeistof in de binnenkant van het apparaat zou komen zet de AEROPAC dan direct uit en maak deze los van de netaansl...

Page 18: ...ndt u op de meegeleverde boorsjabloon Met de AEROPAC hebt u een topproduct van ventilatietechniek aangeschaft Afhankelijk van het model beschikt uw apparaat over de volgende eigenschappen AEROPAC 60 c...

Page 19: ...tussen de buiten en kamerlucht Normaliter stroomt de lucht van buitenaf de kamer in Wijzig de standen van de schuiven om het gewenste luchtvolume in te stellen Modus voor ventilator Open ten minste e...

Page 20: ...sselen van het filter de unit gemakkelijk geopend kan worden Trek met uw vingers licht aan de onderzijde van de kap en klap deze naar voren toe open Het filter is los om de ventilatorkooi gelegd en me...

Page 21: ...mm Elektrische aansluiting AC 230 V 50 Hz 0 05 ampere Veiligheidsklasse 2 AC 230 V 50 Hz 0 11 ampere Veiligheidsklasse 2 Vermogen ca 9 Watt max 25 Watt Kabelaansluiting aan de onderzijde Kabel lengte...

Page 22: ...Voor schade als gevolg van gebreken kunnen wij niet aansprakelijk worden gesteld tenzij wij opzettelijk of nalatig gehandeld zouden hebben resp zwaar of dodelijk letsel te verant woorden zouden hebben...

Page 23: ......

Page 24: ......