background image

12

This manual contains operating instructions for the AEROPAC. Read the manual carefully before 
you start using the equipment for the first time. Please preserve a copy of the present manual care-
fully.

     Use and operation

Use

There are air openings on the sides of the housing 
that you can close with sliders. This prevents un-
desired exchange of air with the environment. 

With the easily controllable fan, you can spread the 
filtered fresh air throughout the room. For this, open 
the air openings at least to some extent. 

Pressure-difference operation

When you switch off the

 

AEROPAC,

 

it works like 

a pressure-difference ventilator. The ventilation then 
takes place through the equalisation of air pressure 
between the external air and the air in the room. 
As a rule, the air from outside flows into the room. 
The wind pressure of the airflow into the room 
changes according to the weather conditions.

Change the slider positions to set the desired air 
quantity.

Fan operation

Open at least one of the two air openings on the si-
de. 

Switch on the unit by turning the adjusting wheel 
clockwise. The background light of the adjusting 
wheel will light up, indicating that the device is in 
operation. The fan will run at its maximum output.
In the AEROPAC 90/90A, the high-speed stage is 
also active, which gets switched-on electronically 
shortly before the “OFF” position of the adjusting 
wheel is reached.

Turn the adjusting wheel further to the right, to easily 
reduce the amount of air inflow.

The markings on the adjusting wheel will make it 
easier for you to find generally preferred settings.

Frontview AEROPAC

Adjusting wheel with

Small power supply line

Air openings

on/off switch

Adjusting wheel 

Tec

hn

ic

a

l s

p

ec

ification

s an

d co

lo

urs

 are

 s

ub

je

ct to c

han

ge

GB

Summary of Contents for AEROPAC 60

Page 1: ...AEROPAC Bedienungsanleitung Operating Instructions Gebruiksaanwijzing DE GB NL H4035 0010de_gb_nl 5...

Page 2: ...nleitung sind zu beachten Gebrauchen Sie das Ger t nur in technisch einwandfreiem Zustand Nehmen Sie keine Ver nderungen an den Ger tekomponenten vor Achten Sie darauf dass die Luft ffnungen frei blei...

Page 3: ...sel stromnetzes Ersetzen Sie das Netzkabel umgehend falls es Knickstellen aufweist oder die Ummantelung besch digt ist Gelangt ein fester Gegenstand oder Fl ssigkeit in das Ger te innere brechen Sie d...

Page 4: ...m AEROPAC erzeugen Sie ein angenehmes Raumklima Bei geschlossenem Fens ter l ften Sie zugfrei sicher energiesparend und ohne L rm von drau en Der AEROPAC ist ein Bel ftungsger t mit einem Radialgebl s...

Page 5: ...ach Wetterlage erh ht Winddruck die Luftstr mung in den Raum Ver ndern Sie die Schieberpositionen um die ge w nschte Luftmengeeinzustellen Gebl sebetrieb ffnen Sie zumindest eine der beiden seitlichen...

Page 6: ...t ziehen Sie einfach an der unteren Kante der Haube und klappen Sie sie nach vorne hoch Abb 1 B ziehen Sie die Haube in dieser Lage vom Ger t ab Abb 2 Der Filter ist lose um den Ventilatork fig gelegt...

Page 7: ...x T 405 x 250 x 115 mm Elektrischer Anschluss AC 230 V 50 Hz 0 05 Ampere Schutzklasse 2 AC 230 V 50 Hz 0 11 Ampere Schutzklasse 2 Leistungsaufnahme ca 9 Watt max 25 Watt Ger tebuchse an der Unterseite...

Page 8: ...n daher bei regelgerechter Anwendung zuverl ssig und sicher Unsere Haftung f r Mangelfolgesch den und oder Schadensersatzanspr che schlie en wir aus es sei denn wir h tten vors tzlich oder grob fahrl...

Page 9: ...documentation from SIEGENIA AUBI Use the unit only in the technically perfect state Do not make any changes on the components of the unit Ensure that the air openings remain clear and are not blocked...

Page 10: ...mains socket Immediately replace the power supply cable if it is kinked or if the jacketing is damaged If a solid object or liquid gets into the inside of the unit switch off and disconnect the unit...

Page 11: ...OPAC is a top class ventilation product The AEROPAC is a ventilation device with a radial fan The device will have the following characteristics depending on the type of model AEROPAC 60 approx 30 60...

Page 12: ...outside flows into the room The wind pressure of the airflow into the room changes according to the weather conditions Change the slider positions to set the desired air quantity Fan operation Open a...

Page 13: ...ring actuated lock so that the appliance can be opened easiliy for a filter change Simply pull on the lower edge of the hood and fold it up to the front Fig 2 The filter sits loosely on the ventilator...

Page 14: ...x T 405 x 250 x 115 mm Power supply AC 230 V 50 Hz 0 05 Ampere Protection class 2 AC 230 V 50 Hz 0 11 Ampere Protection class 2 Power consumption approx 9 Watt max 25 Watt Cable entry at the bottom o...

Page 15: ...We rule out our liability for consequential harm caused by a defect and or for claims for damages unless we have acted wilfully or with gross negligence or respectively are responsible for injury to...

Page 16: ...lleen met de oorspronkelijke accessoires van SIEGENIA AUBI Gebruik de AEROPAC alleen als deze technisch foutloos is Breng geen veranderingen aan onderdelen van het apparaat aan Let erop dat minstens n...

Page 17: ...deze knikpunten vertoont of het omhulsel beschadigd is Als er een vast voorwerp of vloeistof in de binnenkant van het apparaat zou komen zet de AEROPAC dan direct uit en maak deze los van de netaansl...

Page 18: ...ndt u op de meegeleverde boorsjabloon Met de AEROPAC hebt u een topproduct van ventilatietechniek aangeschaft Afhankelijk van het model beschikt uw apparaat over de volgende eigenschappen AEROPAC 60 c...

Page 19: ...tussen de buiten en kamerlucht Normaliter stroomt de lucht van buitenaf de kamer in Wijzig de standen van de schuiven om het gewenste luchtvolume in te stellen Modus voor ventilator Open ten minste e...

Page 20: ...sselen van het filter de unit gemakkelijk geopend kan worden Trek met uw vingers licht aan de onderzijde van de kap en klap deze naar voren toe open Het filter is los om de ventilatorkooi gelegd en me...

Page 21: ...mm Elektrische aansluiting AC 230 V 50 Hz 0 05 ampere Veiligheidsklasse 2 AC 230 V 50 Hz 0 11 ampere Veiligheidsklasse 2 Vermogen ca 9 Watt max 25 Watt Kabelaansluiting aan de onderzijde Kabel lengte...

Page 22: ...Voor schade als gevolg van gebreken kunnen wij niet aansprakelijk worden gesteld tenzij wij opzettelijk of nalatig gehandeld zouden hebben resp zwaar of dodelijk letsel te verant woorden zouden hebben...

Page 23: ......

Page 24: ......