Functional Description of the Connectors/Interfaces
sinudyn-36
Hardware Description 0360520xx
37
/
A shielded cable should be used. Consider the documentation "Unit
Assembly Complying EMC and Supply System Types".
Warning
If no external current reference value is preset, the corresponding an-
alog inputs must be defined as follows: Analog-In+ to +5V, Analog-
In- to -5V. The internal current reference value can also be defined
via the software.
Control
+
-
4,7 k
6
20 k
6
20 k
6
4,7 k
6
3,3 nF
3,3 nF
100pF
100pF
Analog signal
Analog signal
+
-
+
-
Connector X2
Pin
Analog-In 2+
Analog-In 2-
2
1
+
-
20 k
6
20 k
6
4,7 k
6
3,3 nF
3,3 nF
100pF
100pF
Analog-In 1+
Analog-In 1-
3
7
8
6
Analog-Out 1
Analog-Out 2
33 pF
33 pF
1 k
6
Servo module
1 k
6
4,7 k
6