6.3
Module Designation
036XXXX-XX
Current Range
see “Technical Data”
Option XXXX
Voltage Range
C = up to 325 V
DC
F = up to 565 V
DC
Module Width Code
10 = 10 TE module type 01
12 TE module type 03
65 mm module type 05
11 = 12 TE module type 01
14 TE module type 03
13 = 12 TE module type 03
14 = 14 TE module type 03
20 = 105 mm module type 05
Module Type
01 = multi-axis 6 HE
03 = compact 6 HE
05 = compact amplifier, front connection design
Special Design
0 = SIEB & MEYER standard
Communication Module (H)
0 = not available
1 = RS232/RS485
Reference Value Module (S)
0 = not available
1 = CAN-Bus module
036.01.0033
2 = D-Link module
036.01.0034
3 = ServoLink
036.01.0035
5 = RS232 interface
036.01.0036
Sensor Module (M)
0 = not available
2 = sin/cos, EnDat, Hyperface
036.01.0012
3 = Hall-effect sensor evaluation
036.01.0013
4 = resolver (S&M evaluation 12 bits)
036.01.0014
6 = incremental encoder
036.01.0015
7 = 12 bits analog Hall-effect sensor
036.01.0016
Performance Range
Version of the device XXXX
Serial counter. If no version is indicated, the version of the device is 0000. If devices
with different versions are to be changed, the compatibility of the devices must be cleared
up with S & M before.
0360520
DC 4000 0001
Module type
Option
Version of the device
Summary of Contents for sinudyn-0360520 Series
Page 7: ...Symbols 6 Symbols...
Page 13: ...Safety Instructions and Application Advice 12 Safety Instructions Application Advice...
Page 15: ...Unit Assembly Complying EMC 14 EMC...
Page 59: ...Specification of the Digital Inputs and Outputs 58 Hardware Description 0360520xx sinudyn 36...
Page 75: ...General Information Regarding the Wiring 74 Hardware Description 0360520xx...
Page 93: ...Appendix Manufacturers 92 List of Manufacturers...