Functional Description of the Connectors/Interfaces
36
Hardware Description 0360520xx
sinudyn-36
8.2.2
X2 - Analog Signals
X
9-pole male Submin D connector
Standard assignment:
X
Analog-In 1
4
: reference speed value
X
Analog-In 2
4
: current reference value
X
Analog-Out 1: tachometer
X
Analog-Out 2: actual current value
Pin
I/O
Function
1
I
Analog-In 2-
3,4
2
I
Analog-In 2+
3,4
3
I
Analog-In 1+
3,4
4
O
0 V
5
O
-5 V
1
6
O
Analog-Out 2
2
7
I
Analog-In 1-
3,4
8
O
Analog-Out 1
2
9
O
+5 V
1
1
The voltages should only be used for testing. When using a shielded cable the shield must be con-
nected with one end at the metal shield of the 9-pole submin D connector.
2
Outputs 1 and 2. The output signals can be defined in the software (tab page "Devices" > "Analog
signals").
3
Inputs 1 and 2. The input signals can be defined in the software (tab page "Devices" > "Analog
signals").
4
Inputs for differential signals
/
Each
output
of the connector X2 can be loaded with max. 10 mA.
Summary of Contents for sinudyn-0360520 Series