17
5630
6
2019
-
SX35 & SX50
Electrical Specifi cations
EN
MC_0077
MD_0003
Model Size
Voltage
Nominal
current
draw
Min. battery
CCA
Rec. fuse
<7m total + & -
7-14m total + & -
15-21m total + & -
22-28m total + & -
28-35m total + & -
36-45m total + & -
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
Min.
Rec.
*35/140S
12 V
245 A
DIN: 200 SAE: 380 EN: 330
ANL
150
mm2
35
50
50
70
70
95
95
120
120
2 x 70
2 x 70
2 x 95
AW
G
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2 x 2/0
2 x 2/0
2 x 3/0
*50/140S
12 V
370 A
DIN: 350 SAE: 665 EN: 600
ANL
325
mm2
50
50
70
95
120
2 x 70
2 x 70
2 x 95
2 x 95
2 x 120
2 x 120
2 x 120
AW
G
1/0
1/0
2/0
3/0
4/0
2 x 2/0
2 x 2/0
2 x 3/0
2 x 3/0
2 x 4/0
2 x 4/0
2 x 4/0
24 V
170 A
DIN: 175 SAE :332 EN: 280
ANL
150
mm2
25
25
25
35
35
50
35
50
50
70
70
70
AW
G
1
1
1
1
1
1/0
1
1/0
1/0
2/0
2/0
2/0
*80/185T
12 V
530 A
DIN: 550 SAE: 1045 EN: 940
ANL
400
mm2
70
70
120
2 x 70
2 x 95
2 x 95
2 x 120
2x 120
2 x 120
340*
NA
NA
AW
G
2/0
2/0
4/0
2 x 2/0
2 x 3/0
2 x 3/0
2 x 4/0
2 x 4/0
2 x 4/0
24 V
280 A
DIN: 300 SAE:570 EN: 520
ANL
250
mm2
35
35
35
50
50
70
70
95
95
120
120
2 x 95
AW
G
1
1
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2 x 3/0
*100/185T
12 V
740 A
DIN: 750 SAE: 1425 EN: 1320
ANL
500
mm2
95
95
2 x 70
2 x 95
2 x 120
280*
280*
320*
NA
NA
NA
NA
AW
G
3/0
3/0
2 x 2/0
2 x 3/0
2 x 4/0
24 V
340 A
DIN: 400 SAE: 760 EN: 680
ANL
325
mm2
50
50
50
70
70
95
95
120
120
2 x 95
2 x 95
2 x 120
AW
G
1/0
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2 x 3/0
2 x 3/0
2 x 4/0
Control Panel Cable Installation
EN
• All standard Sidepower control panels can be used in any combination as well as any two-way switching device. If an automatic main switch is
installed, a separate switch to control on/off is required.
• Many control panels can be installed using optional Y-connectors or T-connectors if installing an S-link proportional power system.
(NB: If two or
more control panels are operated at the same time in opposite directions, the electronic control box will stop the thruster until it receives
a single signal or thrust in one direction.)
•
When using original Sidepower equipment it is entirely “plug & go” and no additional confi guration setup is required.
•
All controls must have spring load for automatic return to neutral position.
(NB: If the drive direction of the thruster is running opposite to the control panel, swap the blue and grey wire on the control wire or control
box solenoid.
Pin confi guration of 4 pole AMP contact:
Pin1: BLACK = Ground
Pin2: BLUE = Engages thruster SB solenoid
Pin3: GREY = Engages thruster Port solenoid
Pin4: RED
= Positive voltage for the control panel
MC_0041
!
Please refer to the graphic for special considerations relating to your model
!
MG_0115
Thuster
Motor
Automatic Main switch
Manual Main switch
Ext. cable
5-lead
Y cable
5-lead
* 5 LEAD EXTENSION
CABLES
* 4 OR 5 LEAD EXTENSION
CABLES
Ext. cable
5-lead
Thuster
Motor
Ext. cable
4- or 5-lead
Y cable
4- or 5-lead
Ext. cable
4- or 5-lead
Option: Automatic main switch. connects the battery to
the thruster. Operated from the control panel(s).
Requires 5-lead control cables.