O P E R A T I N G I N S T R U C T I O N S | VISIC100SF
Subject to change without notice
MENUS
6
6
Menus
6.1
Start menu
Display
●
Display of the company name and by default the CO sensor.
●
The adjustment tool automatically tries to communicate with a CO sensor.
6.2
Menu tree
6.3
Menu - Nom./Gas/Unit
Function: Set gas type
Display
Table 1: Gas types and measuring ranges
SICK AG
1110
CO
ppm
Menu level
Explanation
Nom./Gas/Unit
Select gas type
Error Status
Display malfunction
Measuring Values
Display measured values
Display Parameters
Display parameters
Software Version
Display software version
Serial Number
Display serial number
Language
Select language
LCD Function
Test hardware function
Installation & Calibration
Read out and change measuring point and system parameters,
perform adjustment
MP Parameters
Read out measuring point parameters
System Parameters
Read out or change system parameters
Operation Data
Read out gas sensor operating data
Calibration
Adjust gas sensor: Zero point and sensitivity
DP1
Select measuring point
Zero DP1
Adjust zero point
Test gas
Set test gas concentration
Nom./Gas/Unit
1110
CO
ppm
Symbol
Description
1110
Type number of the gas sensor used and the gas type
CO
Gas type formula
ppm
Unit
Type
Gas type
Formula
Measuring range
Unit
1110
Carbon monoxide
CO
0–300/0–200
ppm
1129
Nitrogen monoxide
NO
0–100
ppm
1130
Nitrogen dioxide
NO
2
0–5
ppm