CONFIGURING THE CONNECTION SETTINGS
8
69
8027311 / V1-0/2022-04|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TDC-E (Telematic Data Collector)
AnalogInputsModeChange
WebSocket server URL
ws://192.168.0.100:31768/ws/tdce/analog-inputs/mode
MQTT subscription directory
tdce/analog-inputs/mode
Results
{
"AinName":"AIN_A",
"PreviousMode":"Voltage",
"NewMode":"Current"
}
AnalogInputsOvercurrentProtectionChange
WebSocket server URL
ws://192.168.0.100:31768/ws/tdce/analog-inputs/overcurrent-protection
MQTT subscription directory
tdce/analog-inputs/overcurrent-protection-activated
AnalogInputsStateChange
WebSocket server URL
ws://192.168.0.100:31768/ws/tdce/analog-inputs/state
MQTT subscription directory
tdce/analog-inputs/state
Results
{
"AinName":"AIN_A",
"PreviousState":"Inactive",
"NewState":"Active"
}
AnalogInputsValueChange
WebSocket server URL
ws://192.168.0.100:31768/ws/tdce/analog-inputs/value
MQTT subscription directory
tdce/analog-inputs/value
Results
{
"AinName":"AIN_A",
"PreviousValue":0.045,
"NewValue":23.862
}
API
analog inputs