5
Mounting
5.1
Overview of mounting procedure
NOTE
The mounting procedure described here for the device meets the requirements for use
in the target system.
Additional or different requirements may become necessary in the laboratory and dur‐
ing preparation, and should be taken into account as necessary,
. If you have any questions or anything remains unclear in this regard, please
contact our service team.
•
Install the device.
•
Connect the cables.
•
Connecting peripheral devices.
•
Connecting the voltage supply.
5.2
Scope of delivery
•
SIM 2000ST-E
•
4 x grounding screw
•
4 x toothed lock washer
•
Safety note
NOTE
The device is equipped with spring terminals as standard.
5.3
Preparing for mounting
Mounting requirements
•
Select the mounting site:
Plan space requirements and sufficient distance from other devices.
Be aware of the possibility of heat dissipation.
•
Unpack the device and allow to acclimatize to avoid formation of condensation.
Preparing for mounting
1.
Place the device at the mounting site.
2.
Mark the mounting holes.
3.
Proceed to drill the mounting holes.
5.4
Mounting the device
Mounting the device
1.
Set the device on the mounting site.
2.
Fasten device with at least two M5 screws (max. 6 Nm) on opposite device sides
and corresponding washers.
NOTICE
Use self-locking or lock nuts on mounting sites that are exposed to vibrations to prevent
the holding plates from loosening.
MOUNTING
5
8025454/1BLK/2021-03-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | SIM2000ST-E
15
Subject to change without notice