IO-Link master process data (slot 2, subslot 1)
The IO-Link master process data contains the representation of the digital input value
of each pin 2 of all IO-Link ports.
NOTE
This process data module is permanently installed in subslot 1 and cannot be changed.
Data is presented in the following format:
Designation
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Pin 2 inputs
0
0
0
0
0
S4DI2 S3DI2 S2DI2 S1DI2
The parameters have the following meaning:
Designation
Value
Meaning
SxDI2
0
Pin 2 of port x is Low (or deactivated)
1
Pin 2 of port x is High
IO-Link device process data (slot 2, subslots 2 to 5)
Different process data submodules are available for IO-Link ports (slot 2, subslots 2 to
5). Data is presented in the following format:
Submodule
name
Direc‐
tion
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Digital input
On
0
0
0
0
0
0
0
0
SxDI1
Digital output
Off
0
0
0
0
0
0
0
0
SxDO
1
IO-Link 2I / 0O
+ PQI
On
0
2 Byte IO-Link Process Data In
1
2
PQI
7
SIG200 CONFIGURATION
22
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
8017853.1D0S/2021-11-04 | SICK
Subject to change without notice