background image

  

 

TRAINING EQUIPMENT FOR “SAFETY MULTI-BOX”

 

8025381/2020-07-14 

             

 

 

   

 

 

 

 

SHORT OPERATING INSTRUCTIONS |”SAFETY MULTI-BOX” TRAINING EQUIP+DEMOCASE 

SICK AG  |  Waldkirch  |  Germany  |  www.sick.com

  

 

 

 

 

 

 

 

            

 

 

 

 

 

 

 

6

 

Safety function 
 

Initiated by 

 

To reset the safety 
function 

Note 

Example applications 

Initiating stop and 
preventing start 

   

     

 

Intrusion into the protective field 
of the safety laser scanner 
(detection of an object with a 
diameter of approx. 30 mm or 
greater)   

 

 

 

 

Clear the protective field  

+ press the Reset button 

 

 

Operating mode 0, 1 

  

 

When an object enters the warning 
field, the indicator 

 switches to 

yellow. The safety function is not 
triggered. 

 

When an object enters the protective 
field, the indicator 

 switches to red  

 

  

   

  

 

Non-contact protection with 
proximity function 

Initiating a stop  

   

     

       

Intrusion into the protective field 
of the safety light curtain 
(detection of an object of size 
14 mm or greater)   

 

 

 

 

 

Clear the protective field  

+ press the Reset button 

 

 

Operating mode 0, 1 

  

When an object enters the protective 
field, the indicator 

 switches to 

red. 

 

  

   

  

 

Non-contact protection with 
proximity function 

Protection for automated 
material transport 

Warning 
field 

Protective 
field 

105

 

210 

 

445 

300 

26 

11 

27 

27 

18 

29 

11 

30 

18 

Summary of Contents for SAFETY MULTI-BOX

Page 1: ...ctive operating instructions at http www sick com de en Name part number TRAINING EQUIP Safety Multi Box 1097795 DEMOCASE Safety Multi Box 1108579 Technical data Type Training equipment in a case Encl...

Page 2: ...de Safety controller for linking and evaluating the input signals of the safety functions Controls and status indicators for start stop reset unlock inching Indicator for simulating machine movements...

Page 3: ...K AG Waldkirch Germany www sick com 3 Figure 1 Identification of the protective devices and the controls and status indicators on the front side Figure 2 Identification of the protective devices and t...

Page 4: ...ts up red when the machine has been stopped S1 inching button for fast machine operation in MSO 0 manual mode flashes quickly when active S2 inching button for slow machine operation in MSO 0 manual m...

Page 5: ...stop Pressing the emergency stop pushbutton Unlock the emergency stop pushbutton by rotating it press the Reset button Operating modes 0 1 2 Emergency stop safety command Complementary or equivalent...

Page 6: ...ng mode 0 1 When an object enters the warning field the indicator switches to yellow The safety function is not triggered When an object enters the protective field the indicator switches to red Non c...

Page 7: ...on has been pressed In conjunction with physical guards when operating stopping shutting down when the stopping time for a hazardous machine movement is too long when the manufacturing process cannot...

Page 8: ...e is set The machine runs at reduced speed The protective door can be opened using the UNLOCK button The safety functions of the protective door monitoring and the opto electronic protective devices a...