SICK SAFETY MULTI-BOX Short Operating Manual Download Page 5

  

 

TRAINING EQUIPMENT FOR “SAFETY MULTI-BOX”

 

8025381/2020-07-14 

             

 

 

   

 

 

 

 

SHORT OPERATING INSTRUCTIONS |”SAFETY MULTI-BOX” TRAINING EQUIP+DEMOCASE 

SICK AG  |  Waldkirch  |  Germany  |  www.sick.com

  

 

 

 

 

 

 

 

            

 

 

 

 

 

 

 

5

 

Demonstrating safety functions, control functions, operating functions 

 
Note: The response of the safety function is always “Initiate a stop”. 

 

Safety function 
 

Initiated by 

 

To reset the safety 
function 

Note 

Example applications 

Complementary or 
equivalent 
protective measure: 

Emergency stop  

Pressing the emergency stop 
pushbutton  

 

 

 

 

Unlock the emergency 
stop pushbutton 

 by 

rotating it  

+ press the Reset button 

 

Operating modes 0, 1, 2 

 

 

Emergency stop safety 
command 

Complementary or 
equivalent 
protective measure: 

Emergency stop  
 

Pull the rope at the rope pull 
switch  

 

 

 

Reset lever 

 in the 

RUN position  

+ press the Reset button 

 

Operating modes 0, 1, 2 

 

  

Emergency stop safety 
command 

Complementary or 
equivalent 
protective measure: 

Emergency stop  

Pressing the emergency stop 
pushbutton on the rope pull 
switch  

 

 

Reset lever 

 in the 

RUN position  

+ press the Reset button 

 

Operating modes 0, 1, 2 

 

  

Emergency stop safety 
command 

04 

11 

04 

18 

06 

11 

09 

18 

05 

11 

09 

18 

Summary of Contents for SAFETY MULTI-BOX

Page 1: ...ctive operating instructions at http www sick com de en Name part number TRAINING EQUIP Safety Multi Box 1097795 DEMOCASE Safety Multi Box 1108579 Technical data Type Training equipment in a case Encl...

Page 2: ...de Safety controller for linking and evaluating the input signals of the safety functions Controls and status indicators for start stop reset unlock inching Indicator for simulating machine movements...

Page 3: ...K AG Waldkirch Germany www sick com 3 Figure 1 Identification of the protective devices and the controls and status indicators on the front side Figure 2 Identification of the protective devices and t...

Page 4: ...ts up red when the machine has been stopped S1 inching button for fast machine operation in MSO 0 manual mode flashes quickly when active S2 inching button for slow machine operation in MSO 0 manual m...

Page 5: ...stop Pressing the emergency stop pushbutton Unlock the emergency stop pushbutton by rotating it press the Reset button Operating modes 0 1 2 Emergency stop safety command Complementary or equivalent...

Page 6: ...ng mode 0 1 When an object enters the warning field the indicator switches to yellow The safety function is not triggered When an object enters the protective field the indicator switches to red Non c...

Page 7: ...on has been pressed In conjunction with physical guards when operating stopping shutting down when the stopping time for a hazardous machine movement is too long when the manufacturing process cannot...

Page 8: ...e is set The machine runs at reduced speed The protective door can be opened using the UNLOCK button The safety functions of the protective door monitoring and the opto electronic protective devices a...

Reviews: