50
8018478/YWL5/2018-06| SICK
O P E R A T I N G I N S T R U C T I O N S | NAV245
Subject to change without notice
4
ALIGNMENT OF THE SCAN LEVEL
4.5.2
Alignment of the pitch angle
As a second step the pitch angle (graphik on the left side) has to be optimised.
As a preparation the hexagon socket screws 1 and 3 has to loosened to be used as a tur-
ning axis. After loosening the screws 2 and 4 the scanner has to be turned carefully. and
fixed by tightening the screws again. Finally also the hexagon socket screws 1 and 3 have
to be fixed hand-tight.
Fig. 43: adjusting of the pitch angle NAV245
During the adjustement the main focus is on the left side for the best possible pitch angle.
Abb. 44: optimal adjustment of the pitch angle