OUT device connection (female connector, M12, 5-pin, A-coded)
2
1
4
3
5
Table 7: OUT device connection pin assignment (female connector, M12, 5-pin, A-coded)
Pin
Wire color
1)
Designation
Description
1
Brown
Out +24 V DC
Safety switch voltage supply
2
White
In 1
OSSD 1 input
3
Blue
0 V
0 V DC voltage supply
4
Black
In 2
OSSD 2 input
5
Gray
Magnet
Output for magnet activation
24 V DC
1)
Applies to the extension cables recommended as accessories.
b
Pay attention to tightness of the plug connectors.
6.4
Device connection (M12, 8-pin)
Device connection (male connector, M12, 8-pin, A-coded)
8
2
3
4
5
7
1
6
Table 8: Device connection pin assignment (male connector, M12, 8-pin, A-coded)
Pin
Wire color
1)
Designation
Description
1
White
Aux
Application diagnostic output
(not safe)
2
Brown
+24 V DC
Safety switch voltage supply
3
Green
Magnet
Magnet activation 24 V DC
4
Yellow
In 2
OSSD 2 input
2)
5
Gray
OSSD 1
OSSD 1 output
6
Pink
OSSD 2
OSSD 2 output
7
Blue
0 V
0 V DC voltage supply
8
Red
In 1
OSSD input 1
2)
1)
Applies to the extension cables recommended as accessories.
2)
When used as an individual safety switch or as the first safety switch in a cascade: Apply 24 V DC.
b
Pay attention to tightness of the plug connector.
6.5
Connecting a cascade
A safety switch cascade can be created in different ways. Depending on the structure,
end connectors, T-connectors, and nodes are required for voltage supply (
).
6
ELECTRICAL INSTALLATION
24
O P E R A T I N G I N S T R U C T I O N S | MLP1
8020169/ZJN1/2018-03-21 | SICK
Subject to change without notice