Position
Meaning
Description
10
Communication inter‐
face
V = Voltage
A = Current
C = Digital CANopen (250 kbit)
J = Digital SAE J1939 (250 kbit)
P = pulse-width modulation, 5 V signal
11
12
Signal output
10 = current (4 ... 20 mA)
10 = voltage (0.50 ... 4.50 V)
21 = voltage (4.75 ... 0.25 V)
7F = CANopen (node ID 7F Hex)
FD = SAE J1939 (source address JD Hex)
B = pulse width (10 ... 90%)
D = frequency (250 Hz)
13
Connection type
A = M12 4-pin analog / PWM
(1 = V DC; 2 = n.c.; 3 = GND; 4 = SIG)
B = M12 4-pin analog / PWM
(1 = V DC; 2 = SIG; 3 = GND; 4 = n.c.)
M= M12 4-pin analog
(1 = n.c.; 2 = V DC; 3 = GND; 4 = SIG)
K = analog cable connection / PWM 3-wire cable
C = M12 5-pin digital
(1 = n.c.; 2 = V DC; 3 = GND; 4 = CAN_HI; 5 = CAN_LO)
D = M12 5-pin digital
(1 = V DC; 2 = n.c.; 3 = GND; 4 = CAN_HI; 5 = CAN_LO)
14
Connector length
A = strands, 60 mm
1 = connecting cable, 300 mm
15
Measuring range
Position measurement
in 1 mm steps
e.g., 0300 = 50 ... 300 mm
16
17
18
3.3
Construction and function
Construction of the device
1 2
3
4
Figure 1: MAX
®
design
1
M12 connector system
2
Encoder housing (electronics)
3
Position magnet
4
Pressure pipe
Male connector system:
The M12 male connector system requires very little time to attach. It is suitable for
applications in harsh environments up to IP69K (when using a suitable mating connec‐
tor).
3
PRODUCT DESCRIPTION
10
O P E R A T I N G I N S T R U C T I O N S | MAX
®
8022793/1EFT/2021-12-15
| SICK
Subject to change without notice