6.3.2
Connection principle for read mode
"Ethernet"
(Host)
Input 2
à
Input 1
á
Output 1
ß
Output 2
9
Output 3
8
Lector61x
Connection module
2
Image display
SOPAS
SOPAS
"Power/Serial Data/
CAN/I/O"
(Host)
...
...
1 2
V
S
1
GND
HOST
Computer
Further data
processing
"Ethernet" (AUX,
image transfer)
3
V
S
Ethernet
Ethernet
Cable
7
4
6
Reading result
5
Figure 19: Connection block diagram for read mode
1
Supply voltage V
S
2
Connection module CDB650-204 or CDM420-0006
3
Ethernet, AUX interface (image transmission)
4
Image display
5
Read result
6
Data further processing
7
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded/male con‐
nector, DSub-HD, 15-pin)
8
Digital output 3, e.g. for connecting an LED
9
Digital output 2, e.g. for connecting an LED
ß
Digital output 1, e.g. for connecting an LED
à
Digital input 2, e.g. for connecting an incremental encoder
á
Digital input 1, e.g. for connecting a read cycle trigger sensor
6.3.3
Example applications
E
the
rn
e
t
Lector61x
V
S
PC
FTP
9
SOPAS ET
SOPAS ET
Configuration
6
Image display
7
Diagnostics
8
HMI
ß
PLC
3
PLC
3
Digital
inputs
5
Digital
outputs
4
s
e
ri
a
l
2
Ethernet
Serial Data (RS-232), CAN, I/O, Power
C
S
N
(
C
AN
s
e
n
s
o
r
n
e
tw
o
rk
)
1
Figure 20: Facilities for connecting
1
CSN (CAN sensor network)
2
Serial
3
PLC (programmable logic controller)
4
Digital outputs, e.g. for signal lamps
5
Digital inputs e.g. for encoders, photoelectric sensors (trigger sensor)
6
ELECTRICAL INSTALLATION