Type
Lector610
Lector611
1D code types (bar code)
GS1-128 / EAN 128, UPC / GTIN / EAN, 2/5 interleaved, Pharma‐
code, GS1 DataBar, Code 39, Code 128, Codabar, Code 32, Code
93, Plessey Code, MSI/Plessey, Telepen, postal codes
2D code types
Data Matrix ECC200, GS1 Data Matrix, PDF417, PDF417 Trun‐
cated, QR code, MaxiCode
Code qualification
On the basis of ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 15416,
ISO/IEC 18004
No. of codes per reading
interval
1 ... 50 (auto-discriminating)
No. of characters per read‐
ing interval
Max. 500 (for multiplexer function in CAN network operation)
Evaluation time
< 200 μs
> 60 μs
Shutter time
60
μ
s ... 6,000
μ
s
Automatic parameter
switching
Integrated
11.4
Interfaces
Lector610
Lector611
Ethernet
Protocol:
•
TCP/IP
•
EtherNet/IP
•
Modbus
®
TCP
Function: host (data output of the read result)
Function: AUX (service)
1)
Data transmission rate: 10/100 Mbit/s
Services: DHCP, NTP, HTTP, mDNS, DNS-SD, DNS, HTTPS.
MAC address (device-specific), see type label
Serial RS-232
Function: host (data output of the read result)
Data transmission rate: 0.3 kBd ... 115.2 kBd
CAN
Protocol:
•
A connection in a CANopen-based environment is possible. For
additional support, please contact SICK customer service.
•
SICK CAN sensor network CSN (master/slave, multi‐
plexer/server)
Function: host (data output of the read result)
Data transmission rate: 20 kBit/s ... 1 MBit/s
Bus length: maximum 30 m
PROFINET (line topology)
Function: host (data output of read result), PROFINET Single Port
Data transmission rate: 10/100 Mbit/s
Function blocks for various PLC manufacturers are available online
at:
Digital inputs
Type: 2 x physical, switching (“Sensor 1”, “Sensor 2”)
V
in
2)
= maximum 27.6 V, I
in
3)
= max. 5 mA
Opto-decoupled, not reverse polarity protected regarding supply
voltage
Debounce time: adjustable
4)
Encoder frequency: max. 300 Hz
TECHNICAL DATA
11
8024830/1FGB/2022-03-29 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector61x
57
Subject to change without notice