5.3.1.3
Assembling kit variants with an S-mount lens
1
2
3
4
5
6
7
8
9
1
Camera housing
2
Spacer ring (optional)
3
Spacer for integrable illumination
4
Plug connector for illumination
5
S-mount lens
6
Integrable illumination unit
7
Optical filter (optional)
8
Filter holder
9
Protective optics cover
1.
Place the camera housing on a nonslip base.
2.
Remove the protective cap from the round light inlet.
3.
Depending on the lens used and the desired working distance, one or more spacer
rings may need to be mounted below the lens. The spacer rings come in parcels
(part number 2066933 and 2081458).
4.
Screw in the lens unit until the stop point is reached and the thicker part of
the lens is inside the light inlet of the camera housing. If the component is only
screwed in to cover its thread length, it is not tightly screwed into the camera
housing.
5.
If necessary, mount the spacer. Max. recommended torque: 65 Ncm.
6.
Insert the illumination unit connector into the camera housing if necessary.
7.
Mount the illumination unit using the 4 screws. Use hexagon key SW 2 for this
purpose.
8.
Mount the optional filter and filter holder.
9.
Mount the protective optics cover.
5
MOUNTING
24
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
8019946/1EJ6/2022-02 | SICK
Subject to change without notice