5
Mounting
5.1
Overview of mounting procedure
The mounting of the device is divided into the following steps:
•
Mount the device.
•
Align the device with the object.
•
Connect the device to interfaces and supply voltage.
•
Adjust the device.
5.2
Preparation for mounting
5.2.1
Installation requirements
NOTICE
Radio interference may occur when the device is used in residential areas!
■
Only use the device in industrial environments (EN 61000-6-4).
•
Typical space requirement:
see "Field of view diagrams", page 27
and type-spe‐
cific dimensional drawing
•
Comply with the technical data, such as the permitted ambient conditions for
operation,
.
•
Ensure good dissipation of excess heat from the device to the surroundings, in
particular at higher ambient temperatures. Ensure that there is good heat transfer
from the device, for example via the bracket to the mounting base, or ensure that
the back of the device is a sufficient distance from the wall of a housing.
•
Only mount the device using the threaded mounting holes provided or the movable
sliding nuts.
•
Mount the device in a shock and vibration insulated manner.
•
Make sure the device has a clear view of the objects to be scanned.
Auxiliary equipment required
■
Mounting system with sufficient load-bearing capacity and suitable dimensions
■
4 or 2 M5 screws for mounting the device on a mounting system supplied by the
customer
■
Tool and tape measure
The screw length depends on the mounting base (wall thickness of the bracket). When
using an optional SICK mounting system, the screws for mounting the device are
included with delivery.
5.2.2
Mounting systems
Mount the device on the mounting system by means of a minimum of two tapped blind
holes (M5) or sliding nuts.
The threaded mounting holes are located on the rear of the device.
The sliding nuts can each be inserted into a slot on the side of the housing.
SICK offers prefabricated mounting brackets that are optimally suited for mounting the
device,
.
Customer-supplied mounting brackets
A customer-supplied mounting bracket must meet the following requirements:
5
MOUNTING
20
O P E R A T I N G I N S T R U C T I O N S | InspectorP63x Flex C-mount and S-mount
8019946/1EJ6/2022-02 | SICK