6.3.2
Connection principle for operation mode
"Ethernet"
(Host)
Input 2
à
Input 1
á
IN/OUT 3
ß
IN/OUT 4
9
IN/OUT 5
8
InspectorP61x
Connection module
2
Image display
SOPAS
SOPAS
"Power/Serial Data/
CAN/I/O"
(Host)
...
...
1 2
V
S
1
GND
HOST
PC
Further data
processing
"Ethernet" (Aux,
image transfer)
3
V
S
Ethernet
Ethernet
Cable
7
4
6
Reading result
5
Figure 19: Connection block diagram for operation mode
1
Supply voltage V
S
2
Connection module CDB650-204 or CDM420-0006
3
Ethernet, Aux interface (image transmission)
4
Image display
5
Read result
6
Data further processing
7
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded / male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded / male con‐
nector, DSub-HD, 15-pin)
8
Configurable digital input/output 5 (e.g. for external control, external light or result com‐
munication)
9
Configurable digital input/output 4
ß
Configurable digital input/output 3
à
Digital input 2, e.g., for connecting an incremental encoder
á
Digital input 1, e.g., for connecting a read cycle trigger sensor
6.3.3
Example applications
E
the
rn
e
t
InspectorP61x
V
S
PC
FTP
8
SOPAS ET
SOPAS ET
Configuration
5
Image display
6
Diagnostics
7
HMI
9
PLC
2
PLC
2
Digital
inputs
4
Digital
outputs
3
s
e
ri
a
l
1
Ethernet
Serial Data (RS-232), I/O, Power
Figure 20: InspectorP61x: connection options
1
Serial
2
PLC (Programmable Logic Controller)
6
ELECTRICAL INSTALLATION
32
O P E R A T I N G I N S T R U C T I O N S | InspectorP61x
8026257//2020-12 | SICK
Subject to change without notice