Commissioning
1
Observe the application conditions: Adjust the distance between the sender and the receiver
according to the corresponding diagram (x = sensing range, y = operating reserve).
If several through-beam photoelectric sensors which are installed next to one another are to
be used, we recommend swapping the sender/receiver arrangement at every second
through-beam photoelectric sensor and ensuring that there is sufficient distance between
the through-beam photoelectric sensors. By doing this, mutual interference can be preven‐
ted.
Image 3: H
2
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK range
of accessories). Align the sender and receiver with each other [K].
Observe the maximum permissible tightening torque of the sensor of 2.0 Nm for metal/0.9
Nm for plastic [K].
Image: K: GRSE18-x24x7
Commissioning