Flange-to-flange unidirectional
Fitting the FLOWSIC600-XT for unidirectional flange-to-flange use.
Fig. 22
Unidirectional flange-to-flange use
NOTICE:
Meters must be designed as full-bore devices for a continuous series
connection with flange-to-flange mounting of the two gas meters. Likewise, the
ultrasonic transducer frequency of both meters must be designed different in
order to avoid possible mutual interference. This is particularly true when using
SICK and non-SICK device combinations.
NOTICE:
Installation configuration (B) with the flow conditioner refers exclusively to SICK
conditioner types (according to SICK documents 9211778 and 9211779).
When using conditioner types CPA 50E or 55E, a distance between the condi
-
tioner and meter of at least 10DN inlet length must be considered. When other
conditioners are used, the installation configuration can be different and must
be agreed with SICK.
NOTICE:
During operation, it is imperative to use the same flow conditioner as well as
the same pipes, in the same orientation as when calibrating the meter. Mark
the pipes and flow conditioner to indicate the flange alignment at the time of
calibration.
≥ 3 DN
1 ... 5 DN
C
B
1
3
4
B
A
≥ 3 DN
1 ... 5 DN
≥ A
1
3
2
2
≥ A
1. FLOWSIC600-XT (8 paths)
2. FLOWSIC600-XT (4+1 paths)
3. Alternative temperature measuring points
4. SICK flow conditioner