Installation
FLOWSIC60 · Operating Instructions · 8014241/YTG9/V1-0/2016-02 · © SICK Engineering GmbH
33
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
3.2.4
Electrical installation of Signal Processing Unit
After mounting the SPU on the tunnel wall, the terminal connections in the SPU must be
wired.
Loosen grub screw by 1-2 turns on neck of SPU (DIN 913 M5x20 45H) using a 2.5mm
Allen key
Turn complete SPU housing 90° in a clockwise direction
Repeat steps in reverse following wiring of the terminal connections
Fig. 15
Access to terminal connections
Opening the rear housing cover
Loosen the securing clip using a 3 mm Allen key.
Unscrew the rear housing cover in a counter-clockwise direction and remove.
A schematic wiring diagram is provided on the inside of the rear housing cover
.
Figure 16
SPU housing
Grub screw
NOTICE:
Lubricant
Only use LOCTITE 8156a as lubricant for rear housing cover. Apply the
lubricant sparingly.
Open the cover
Cover
Securing clip