Installation FLSE100-XT
FLOWSIC100 Flare-XT · Operating Instructions · 8023761/V1-0/2020-10 · © SICK Engineering GmbH
43
Table 3
Overview of parts with process gas contact
5.4
Spool piece option
The FLOWSIC100 Flare-XT can also be fitted with an optional spool piece to reduce
geometric uncertainty of device installation and to simplify assembly. The exact design
(nominal diameter, connection, material) always depends on the customer specifications.
The installation length of the spool piece depends on the nominal diameter of the pipe:
– Installation length 800 mm for pipe diameter up to 28”
– Installation length 1100 mm for pipe diameter 30” ... 60”
– Installation length for pipe diameter >60”...72” on request
All system solutions (FLOWSIC100 Flare-XT + spool piece) are optionally available with
pressure and temperature sensors. For the positioning of pressure and temperature
transmitters the following configurations are available:
– Spool piece with standard installation length with integrated pressure tapping,
temperature sensor 5 D
T
( = 5 * diameter of the thermowell) in the outflow area
– Spool piece, extended length with integrated pressure and temperature tapping.
Fig. 15
Spool piece option (example)
Material
Component
Type FLSE100-XT
F1F-S F1F-M F1F-H F1F-P
Stainless steel
1.4404
Retraction flange (7), threaded ring (2)
x
x
x
x
Connection for optional venting (11), retraction nozzle (6)
x
x
x
x
Duct probe (10), sensor contour (13), transducer and contour holder
(18), transducer pipe screw fitting (17)
x
Adjusting ring (14), pipe screw fitting (1), sealing disc (4)
x
x
x
x
Titanium
Duct probe (10), transducer assembly (8)
x
x
x
Transducer assembly (8), probe tube (16)
x
PTFE
Centering (12)
x
x
x
x
Sensor contour (9)
x
x
x
Thrust ring (15)
x
PTFE/graphite
Sealing profile (5)
x
x
x
x
Stainless steel
1.4568
Spring (3)
x
x
x
x
800 mm