Technical data
FLOWSIC100 Flare-XT · Operating Instructions · 8023761/V1-0/2020-10 · © SICK Engineering GmbH
163
12.5
Applications of FLOWSIC100 Flare-XT in a regulated environment
The gas flow meter can be used for emission measurements, which may be subject to one
or more regulations in some jurisdictions. Compliance with all emission regulations
applicable at the site of the installation remains the responsibility of the owner / operator.
When correctly designed and applied, SICK's ultrasonic flow technology meets or exceeds
most regulatory performance requirements. Please contact your SICK representative to
find out about the right flare measurement solution that meets the currently applicable
regulatory requirements.
12.6
Application ranges
Fig. 101
Exemplary V
max
of 1-path and 2-path solutions dependent on the sound velocity (SOS)
Fig. 102
V
min
with 20% uncertainty of 1-path and 2-path solutions depending on the speed of sound (SOS)
50
60
70
80
90
100
110
0
10
20
30
40
50
60
70
80
130
40
v
max
in f
t/s
Nominal pipe size in ″
120
1-path sos = 340 m/s
1-path sos = 430 m/s
1-path sos = 650 m/s
2-path sos = 340 m/s
2-path sos = 430 m/s
2-path sos = 650 m/s
V
m
ax
[m
/s
]
1-path SOS = 340 m/s
2-path SOS = 340 m/s
1-path SOS = 450 m/s
2-path SOS = 450 m/s
1-path SOS = 650 m/s
2-path SOS = 650 m/s
Nominal size ["]
0.04
0.05
0.06
0.07
0
10
20
30
40
50
60
70
80
0.08
0.03
v
min
in m/s
Nominal pipe size in ″
0.09
0.10
0.11
0.12
0.13
0.14
0.15
0.16
0.17
0.18
0.19
1-path sos = 340 m/s
1-path sos = 450 m/s
1-path sos = 650 m/s
2-path sos = 340 m/s
2-path sos = 450 m/s
2-path sos = 650 m/s
1-path SOS = 340 m/s
2-path SOS = 340 m/s
1-path SOS = 450 m/s
2-path SOS = 450 m/s
1-path SOS = 650 m/s
2-path SOS = 650 m/s
V
m
in
[m
/s
]
Welded / dry calibrated / flow calibrated
Nominal size ["]