PRODUCT DESCRIPTION
3
3
Product description
3.1
Flow-X flow computer
The Flow-X flow computer consists of 1 to 4 Flow-X modules (Flow-X) and an enclosure
(Flow-X/S, Flow-X/P or Flow-X/C). For a Flow-X/S or Flow-X/P enclosure, the Flow-X modules
are exchangeable whereas for a Flow-X/C, the Flow-X module is permanently installed inside
and therefore cannot be exchanged.
3.2
Flow-X Module
The Flow-X module is the core element and represents the complete gas flow computer. It
represents a measuring section in a gas measuring system. The Flow-X module is operated
in a Flow-X/S, Flow-X/P or Flow-X/C enclosure. It has its own 4-inch display and four
navigation keys which serve to check values and change parameters.
Fig. 1: Flow-X module
Signal type
Qty.
Specification
Analog inputs
6
[1]
Analog transmitter input, high accuracy
Input types: 4 … 20 mA, 0 … 20 mA, 0 … 5 V, 1 … 5 V
Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full
ambient range of 0 ... 60°C, long-term stability 0.01%/year,
resolution 24 bit.
Analog inputs share a common, floating ground in relation to all
other electronics.
4-wire PRT inputs
2
Resolution 0.02 °C for 100 Ohm input.
Error depending on range 0 ... 50 °C: Error <0.05 °C or better
-220 ... +220 °C: Error <0.5 °C or better
HART input
4
[1]
Independent HART current loop inputs, in addition to the
4 ... 20 mA signals (analog inputs)
Support includes multi-drop for each measuring section and
support for redundant flow computer operation
Analog outputs
4
Analog output for process outputs and flow/pressure control,
resolution 14 bit, 0.075% FS.
Analog inputs share a common, floating ground in relation to all
other electronics.
Pulse inputs
4
[2]
Single or double pulse input.
Adjustable trigger level at different voltages.
Frequency range up to 10 kHz for single and double pulse.
Compliant with ISO6551, IP252 and API 5.5.
True Level A and Level B implementation.
Table 1:
Flow
-
X/M inputs and outputs