Teach in the current distance as a reference background for the inverted ObSB mode for Q
1
in
the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Q
1
/
to → Q
1
not
Align the sensor with the reference background
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
-
Manually set the desired distance of the reference background for ObSB mode for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
→
3
0000 (Note:
3
= flashing 3)
/
,
/
,
/
,
/
,
/
to → distance to reference background in mm
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
30,000 mm
Manually switch the logic for Q
1
to “Low Active”
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
/
to → Q
1
Logic
→ High Active
/
to → Low Active
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= ObSB (Background)
Factory setting:
High Active
6
OPERATION
34
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro