![SICK DT50-2 Pro Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/sick/dt50-2-pro/dt50-2-pro_operating-instructions-manual_1263899025.webp)
Teach in the current distance as a single or DtO switching point for Q
1
in the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Q
1
Position object
→ Saved
to → RUN mode
Necessary default settings:
Factory setting or mode Q
1
= DtO (1
point)
Factory setting:
30,000 mm
Teach in the current distance as an inverted single or DtO switching point for Q
1
in the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Q
1
/
to → Q
1
not
Position object
→ Saved
to → RUN mode
Necessary default settings:
Factory setting or mode Q
1
= DtO (1
point)
Factory setting:
-
Manually teach in the desired distance as a single or DtO switching point for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
→
3
0000 (Note:
3
= flashing 3)
/
,
/
,
/
,
/
,
/
→ desired distance in mm
→ Saved
to → RUN mode
Necessary default settings:
Factory setting or mode Q
1
= DtO (1
point)
Factory setting:
30,000 mm