Change the analog output behavior to “falling”
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Manual Q
a
→ 4 mA
/
to → Q
a
Logic
→ Rising
/
to → Falling
→ Saved
to → RUN mode
Necessary default settings:
Factory setting or function Q
2
/Q
a
=
4-20 mA or 0-10 V
Mode Q
a
= Distance (only for user
level = Advanced)
Factory setting:
Rising
6.4.4.2
“Shape comparison” (“Shape”) analog mode
6.4.4.2.1
Description
The “Shape comparison” analog mode is only accessible if the Advanced user level and
an analog function for Q
2
/Q
a
are activated. During the shape comparison, the shape of
a measured object is compared to a reference shape that was previously taught in. The
sensor outputs an analog signal in accordance with the match level.
20.5
20.0
4.0
3.5
Min.
Max.
mA
2
1
Figure 27: 4-20 mA output function in shape mode with rising output behavior
1
Taught-in or manually set match for bad objects
2
Taught-in or manually set match for good objects
10.0
0
Min.
Max.
V
2
1
Figure 28: 0-10 V output function in shape mode with rising output behavior
1
Taught-in or manually set match for bad objects
2
Taught-in or manually set match for good objects
6
OPERATION
54