8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 45
IO-Link interface
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
66 (0x42)
Bit filter for switch
-
ing output/outputs
UINT8
R/W
• 0: OFF
•
2: Filter depth 2
• 4: Filter depth 4
• 8: Filter depth 8
• 16: Filter depth 16
Filter depth 4:
Four consecutive
measured values
must exceed or
fall below the con-
figured switching
point in order
for the switching
output to react.
Defines how often in
succession the switch-
ing condition (e.g.
exceeding switching
point Q1 far) must
be fulfilled before the
status of the switching
output changes. The
bit filter affects only
the switching output
behavior, not the
process data or the
analog output.
Devices up to date
code
2033
xxxx:
Writable only if the “0:
Expert” was selected
for index “103”.
Devices from date
code
2034
xxxx:
Writing automatically
generates the selec-
tion “0: Expert” for
index “103”.
1)
SICK-specific service data – sensor performance