IO-Link interface
44
© SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
64 (0x40)
Integration time
measurement or
output rate
UINT8
R/W
• 0
• 1
• 2
•
3
• 4
• 5
• 6
• 7
• 8
DT35 and DS35 red
laser, class 1 devices:
Integration time mea-
surement or output
rate 2
n
* 2 ms,
All other devices:
Integration measure-
ment or output rate 2
n
* 1 ms
Devices up to date
code
2033
xxxx:
Writable only if “0:
Expert” was selected
for index “103”.
Devices from date
code
2034
xxxx:
Writing automatically
generates the selec-
tion “0: Expert" for
index “103”.
67 (0x43)
Averaging
UINT8
R/W
• 1: OFF
•
2: Filter depth 2
• 4: Filter depth 4
• 8: Filter depth 8
• 16: Filter depth 16
Sliding averaging over
x measured values. Af-
fects only process data
and analog output, not
switching behavior.
Devices up to date
code
2033
xxxx:
Writable only if the “0:
Expert” was selected
for index “103”.
Devices from date
code
2034
xxxx:
Writing automatically
generates the selec-
tion “0: Expert” for
index “103”.