8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 43
IO-Link interface
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
80 (0x50)
Q2 analog far
UINT16
R/W
50 … 50000 mm
DT35: 10000
DL35: 50000
DS35/DR35: –
In 1 mm steps
96 (0x60)
Q2 analog
near-far-center
displacement
UINT16
R/W
50 … 50000 mm
DT35: 5025
DL35: 25100
DS35/DR35: –
In 1 mm steps
93 (0x5D)
Q1/Q2 signal level
warning (OWS)
threshold
UINT16
R/W
0 … 65535
–
→
See Chapter 10.1
65 (0x41)
Q1/Q2 inversion
Record
R/W
•
0: Q1 and Q2 not
inverted
• 1: Only Q1 inverted
• 2 Only Q2 inverted
• 3: Q1 and Q2
inverted
Bit 0: Q1
Bit 1: Q2
Bit 2 … 7: reserved
106 (0x6A)
Distance offset
UINT16
R/W
0
… 50000
In 1 mm steps
97 (0x61)
Time function for
switching output/
outputs
UINT8
R/W
•
0: Disabled
(deactivated)
• 1: ON delay
• 2: OFF delay
• 3: ON/OFF delay
• 4: One-shot
98 (0x62)
Time for time
function
UINT8
R/W
0 … 255 ms
In 1 ms steps
Table 15:
SICK-specific service data – outputs
9.3.3
SICK-specific – sensor performance
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
103 (0x67) Response time
UINT8
R/W
• 0: Expert
• 1: Super-slow
•
2: Slow
• 3: Medium
• 4: Fast
• 5: Super-fast
2
Devices up to date
code
2033
xxxx:
Index 64, 67 and 66
are only available if
“0: Expert” has been
selected.
Devices from date
code
2034
xxxx:
As soon as index 64,
67 or 66 has been
rewritten, “0: Expert” is
automatically set.