CLV 41x Bar Code Scanner
Ø
Setup with CLV Setup software (change parameter set)
1. Connect the PC to the CLV
(see also Section
8.4 Connecting the PC to the CLV)
2. Start the CLV Setup program on the PC
(see also Section
10.5 Parametrization with the CLV Setup software)
3. Upload the configuration from the CLV
4. Change the configuration cards as required.
The parameters and their functions are explained in the online help.
5. Download the configuration to the CLV and store the values permanently
6. Save the modified parameter set on the PC as a configuration file!
Alternative:
5. Print out the profile bar codes and present them to the CLV in the specified
sequence
(see also Section
10.3 Profile programming)
Ø
Setup with command strings from the host
(not described here, further information is available on request)
Alternative
procedure
10. 2 Default settings
A concise overview of the default CLV settings that are effective when the device is
switched on for the first time after delivery is shown in
Table 11
.
The tried-and-tested default parameters have been selected so that CLV can be
used directly in many applications without requiring modification.
Parameter
Default setting (CLV 410)
Code types (active)
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5
Interleaved
Code length
Freely definable (all code types, except EAN and UPC, 2/5 Interleaved: 4...50
characters)
Multiple read
3 (all code types)
Min./max. no. of codes
1
Resolution
0.5 mm
Scanning frequency
500 Hz
Min. reading distance
50 mm
Reading pulse generation Start: polling reflector End: polling reflector
Beeper
Result function: Good Read, volume: low
Switching outputs
Result 1: Device Ready; Result 2: Good Read; Result 3: No Read
Protocol (Host)
Start character: STX, stop character: ETX
Transmission rate (host)
9600 bits/s
Data format (host)
8 data bits, no parity, 1 stop bit
Output format (host)
Header: blank, separator: blank, terminator: blank, error string: separator
Output sequence
Code position
Output time
Read result: end of pulse
Separator: after code
Test string
Inactive
Table 11
TIP:
You can call up the entire default settings from the CLV Setup program as follows:
Ø
Choose F
ACTORY
D
EFAULTS
in the F
ILE
menu or
Ø
Click the symbol.