CLV 41x Bar Code Scanner
© SICK AG • Auto Ident • Germany • All rights reserved
17
Operating Instructions
8 008 224/I982/08-00
10. Power on and setup
10. 1 Step-by-step setup instructions
Ø
Setup with the default settings
1. Connect the CLV to the 4.5...30 V DC power supply
(see also Section
8.1 Pin assignment of the connector
)
2. Align the CLV with the white polling reflector supplied (special code),
distance approx. 300 mm
(see also Section
9.2 Mounting the polling reflector
)
3. Present the bar code sample above at a distance of approx. 200 mm and
cover the polling reflector
(see also Section
10.6.1 Reading mode
)
4. Uncover the polling reflector again
The CLV confirms that the read was successful with acoustic signal from the
beeper and the Result LED lights up
5. The CLV can now be operated with the default settings!
(see Section
10.2 Default settings of the CLV
for the default settings)
Ø
Setup with profile bar codes (change parameter set)
1. Present the required printed profile bar code(s) on the card supplied
to the CLV
The CLV confirms every good read of the profile bar code with an acoustic signal
from the beeper. If a further bar code is not presented to the CLV within 10 s, the
CLV switches to Reading mode and outputs two consecutive acoustic signals
(see also Section
10.3 Profile programming)
2. The CLV can now be operated with the modified settings!
Ø
AutoSetup (modified code configuration)
1. Present bar code no. 10 to the CLV
The CLV confirms the start of AutoSetup by means of an acoustic signal from the
beeper and the Result LED lights up for an extended period of time.
(see also Section
10.4 AutoSetup)
2. Present the application-specific bar code to the CLV at the maximum
reading distance in the application
The CLV confirms the good read by means of an acoustic signal from the beeper
and the Result LED lights up. It then switches to Reading mode and outputs two
consecutive acoustic signals.
3. The CLV can now be operated with the modified code configuration!
The code type presented to the CLV is then evaluated
Bar code sample
Code type:
Code 39
Module width: 0.5 mm
Quick start
Profile
programming
Teaching in application-
specific bar codes
U
V
W
X
Y
Z