Operating Instructions
8 008 224/I982/08-00
CLV 41x Bar Code Scanner
Fig. 4. Connecting the host interface
The default communication parameters of the CLV host interface are as follows:
Parameter
Value
Data transmission rate
9600 bit/s
Data bits
8
Parity
none
Stop bit
1
Protocol
Sick (start character: STX, stop character: ETX, no
repeat request: none, timeout: 50 ms)
Table 6
The parameters can be changed in the D
ATA
F
ORMAT
and I
NTERFACE
P
ROTOCOL
fields on
the H
OST
I
NTERFACE
card of the user interface.
By reading in profile bar code nos. 11 and 12 (
Section 10.2 Default setting
), you can
define the above default settings temporarily with a different parameter set to allow
the PC to communicate with the CLV.
8. 5. 2 Connecting the functional interfaces
Sensor 1 switching input
In order to trigger a reading process, the CLV requires a suitable clock pulse in
Reading mode that signals the presence of a conveyor object in the reading field.
The clock pulse generates the reading interval (time window for evaluation) internally
in the CLV. In the default setting, the reading pulse is supplied by means of internal,
continuous reflector polling (see
Section 9.2
).
If an external sensor (e.g. photoelectric switch, switch) is to notify the CLV of the
presence of a conveyor object, the following steps must be performed:
Ø
Connect the sensor to the CLV as shown in
Fig. 5
TIP:
IMPORTANT
RxD
TxD
GND
RD+
RD–
TD+
TD–
GND
Term
TxD
RxD
GND
TD+
TD–
RD+
RD–
GND
10
11
5
6
7
8
9
5
4
CLV 410
Host
RS 422
CLV 410
Host
RS 232
RS 485 (SICK Network): Connection diagram available on request
Terminal assignment
AMV 40-011/AMS 40-012, -013:
T. 6
T. 7
R+
R-
T. 8
T. 9
T+
T-
T. 5
GND
T. 10
T. 11
RxD
TxD
GND
T. 5