Object 2019h – Process Cycle Time
Either the internal or the external cycle time is output via this object.
Table 137: Object 2019h
Object
Access
Data type
Designation
Description
Data values
2019h
R
UINT-32
Process Cycle Time
Cycle time in µs
250 … 100.000
Object 2022h – Diagnosis Service Parameter
Only available if bit 12 is enabled in object 6000h.
Table 138: Object 2022h
Object Sub‐
index
Access
Data type
Designation
Description
Data values
2022h
R
Record
Diagnosis Service
Parameter
-
.0
R
UINT-8
Number of entries
15
.1
R
UINT-32
Number of Switch-On
Power-up counter
-
.2
R
UINT-32
Operating Time Mov‐
ing
Operating time in
s, the time during
which the encoder has
moved is output
1
-
.3
R
UINT-16
Max. Operating Speed
Maximum speed in
rpm since the encoder
has been in operation.
-
.4
R
UINT-32
Starts with Direction
Forward
Counter for start of
the encoder in forward
direction
1
-
.5
R
UINT-32
Starts with Direction
Backward
Counter for start of
the encoder in back‐
ward direction
1
-
.6
R
UINT-32
Starts with Alternating
Directions
Counter for the num‐
ber of direction
changes
1
-
.7
R
UINT-32
Operating Hours coun‐
ter
Operating hours coun‐
ter (× 0.1 h)
-
.8
R
INT-16
Min. Operating Tem‐
perature
Minimum operating
temperature in °C
-
6