Object 2009h – Network Configuration
Table 124: Object 2009h
Object Sub‐
index
Access
Data type
Designation
Description
Data values [default value]
2009h
R/W
Record
Network Configuration -
.0
R
UINT-8
Number of entries
3
.1
R/W
UINT-32
Access Code
Write protection for
the following parame‐
ters
98127634h
.2
R/W
UINT-8
Node-ID
Node address of the
encoder in CANopen
1 ... 127
[5]
.3
R/W
UINT-8
Baud rate index
0 ... 8
[4]
6.5.2
Objects that provide status information
Object 2010h – STW-1 – Device Status Word
Table 125: Object 2010h
Object Sub‐
index
Access
Data type
Designation
Description
Data values
2010h
R
Array
UINT-16
STW-1 – Device Status
Word
-
.0
R
UINT-16
Number of entries
3
.1
R
UINT-16
State Flag 1, S_STAT-A 0000h … FFFFh
.2
R
UINT-16
State Flag 2, S_STAT-B 0000h … FFFFh
.3
R
UINT-16
State Flag 3, S_STAT-C 0000h … FFFFh
Table 126: Object 2010h – State Flag 1 (S_STAT-A)
Bit
Description
Error code of the emer‐
gency message
15
Memory error:
Invalid EEPROM checksum on initialization
5080h
14
Reserved
-
13
Error of the Sync multi counter:
•
Speed exceeds the upper limit of 12,500
rpm
or
•
Number of current errors on the calculation
of the singleturn position above the limit of
10 errors
1060h
12
Reserved
-
11
Position error:
Invalid or no synchronization from the single‐
turn counter to the multiturn counter
5051h
10
Positionsfehler:
Singleturn position incorrect
5050h
9
Position error:
Error on the calculation of the vector length
Sin² + Cos² in the multiturn stage
5051h
OBJECT LIBRARY
6
8016869/1EF3/2021-12-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | AHS/AHM36 CANopen
AHS/AHM36 CANopen Inox
73
Subject to change without notice