Objekt 1017h – Heartbeat Time
Table 58: Objekt 1017h
Objekt
Access
Data type
Designation
Description
Data values
1017h
R/W
UINT-16
Heartbeat Time
Heartbeat cycle time
in ms. With the value
0 the heartbeat is
inactive.
0000h … 7FFFh
Object 1018h – Identity Object
Table 59: Object 1018h
Object Sub‐
index
Access
Data type
Designation
Description
Data values
1018h
R
Record
Identity Object
-
.0
R
UINT-8
Number of entries
4
.1
R
UINT-32
Vendor ID
01000056h = SICK
.2
R
UINT-32
Product Code
00007721h = AHS36
Basic
00007722h = AHM36
Basic
00007723h = AHS36
Advanced / Inox
00007724h = AHM36
Advanced / Inox
.3
R
UINT-32
Revision Number
00010001 = 1.01
(depending on the release)
.4
R
UINT-32
Serial Number
JJWWxxxx (Jahr/
Woche/ fortlaufende
Nummer)
Table 60: Object 1018h – details
Bit
Designation
31 ... 24
Device Code
23 ... 16
YY (Jahr)
15 ... 10
WW (Woche)
9 ... 0
Sequential number
6.3
Process Data Objects
The process data objects are used to define which objects are transmitted to the
control system or received from the control system and in which manner. The AHS/
AHM36 CANopen and AHS/AHM36 CANopen Inox supports one Receive PDO and four
Transmit PDOs.
•
Data are received from the PLC by the encoder using the Receive PDO. The
mapping for this PDO is fixed and cannot be modified.
•
Data are sent by the encoder to the PLC using the four Transmit PDOs. The
mapping for these PDOs is variable and can be modified.
Both the Receive PDO and the four Transmit PDOs are defined each in two objects.
•
The Receive PDO is defined by the following objects:
6
OBJECT LIBRARY
50
O P E R A T I N G I N S T R U C T I O N S | AHS/AHM36 CANopen
AHS/AHM36 CANopen Inox
8016869/1EF3/2021-12-08 | SICK