![SICK A3M60 Advanced Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/sick/a3m60-advanced/a3m60-advanced_operating-instructions-manual_1264516025.webp)
Technical specifications
Operating Instructions
Chapter
6
25
8014012/1EF3/2021-12-08
Subject to change without notice
© SICK AG
•
Germany
•
All rights reserved
Minimum
Typical
Maximum
A3M60 Basic
Electrical data
Operating voltage
10 V
30 V
Power consumption
1.5 W
Resolution
Per revolution
8,192
Revolutions, total
8,192
Repeat accuracy
±
0.25
°
Error limit
±0.5°
PROFIBUS
Protocol
DP<V0 (EN 50 170<2)
Interface
RS<485
Transmission speed
12 MBaud
Programmable parameters
Resolution, direction of rotation
General data
Enclosure rating
Housing
IP 67 (EN 60 529)
Shaft
IP 65 (EN 60 529)
Operating temperature range
–
10°C
+70°C
Storage temperature range
–
40°C
+100 °C
max. 24 h
Permissible relative humidity
95 %